SysComAsyncFB.SysComCloseAsync (METH)

METHOD SysComCloseAsync : RTS_IEC_HANDLE

<description>Close a com port asynchronously</description> <result><p>RESULT: Returns the runtime system error code (see CmpErrors.library).</p></result>

InOut:

Scope

Name

Type

Comment

Return

SysComCloseAsync

RTS_IEC_HANDLE

Input

pParam

POINTER TO tSysComClose

<param name=”pParam” type=”IN”></param>

pudState

POINTER TO UDINT

<param name=”pudState” type=”IN”>State of the async job. See CmpAsyncMgr.GVL.ASYNCSTATE_ definitions in CmpAsyncMgr.library.</param>

pResult

POINTER TO RTS_IEC_RESULT

<param name=”pResult” type=”OUT”>Pointer to runtime system error code (see CmpErrors.library)</param>