TraceMgrPacketReadFirst2
(FUN)
FUNCTION TraceMgrPacketReadFirst2 : RTS_IEC_HANDLE
Reads the contents of the first record, starting at a given time stamp.
Only entries with a time stamp greater than or equal to ulTimestamp are copied. If the time stamp is zero, the function behaves like TraceMgrPacketReadFirst.
Note
if the result code is ERR_ENTRIES_REMAINING, data has been successfully copied to pTraceBuffer, but more data can be read by a subsequent call. (Either because the destination buffer was too small, or because new data has been recorded in the mean time.)
Note
You should call TraceMgrPacketReadBegin before calling this function, to make sure any outstanding trace values are written to the trace buffers.
Note
Data is always returned in little endian byte order even if the device has big endian byte order.
- InOut:
Scope
Name
Type
Comment
Return
TraceMgrPacketReadFirst2
RTS_IEC_HANDLE
- Returns the runtime system error code (see CmpErrors.library):
ERR_PARAMETER if hPacket is not a valid packet handle
ERR_NO_OBJECT if the packet does not have a single record
ERR_NOTINITIALIZED if the packet is not complete
ERR_TIMEOUT if reading took too long
ERR_ENTRIES_REMAINING if more data can be read by a subsequent call (this is not an error)
Input
hPacket
RTS_IEC_HANDLE
The trace packet handle
ulTimestamp
UDINT
The time stamp (relative to the trace start time) from where to start copying
Inout
pTraceBuffer
Pointer to the destination buffer
pulReadBytes
UDINT
Size of the destination buffer in bytes (in), number of bytes copied (out)
pResult
RTS_IEC_RESULT
The result code