IoProdEntryRead (FB)

FUNCTION_BLOCK IoProdEntryRead EXTENDS AbbETrig

Read production data out of the I/O - Modules with Firmware >= V3.0

InOut:

Scope

Name

Type

Initial

Comment

Inherited from

Input

Execute

BOOL

FALSE

A rising edge starts the operation, the output Busy goes to TRUE. In the first cycle all other inputs are read and stored, afterwards they are ignored. A falling edge does not stop the operation. After Done = TRUE or Error = TRUE and Execute = FALSE all outputs will be reset.

AbbETrig

Output

Done

BOOL

FALSE

Operation is completed without error (while outputs Busy and Error are FALSE). This output is TRUE for at least one cycle or until Execute is set to FALSE

AbbETrig

Busy

BOOL

FALSE

Operation is running (while outputs Done and Error are FALSE)

AbbETrig

Error

BOOL

FALSE

Operation is stopped with error (while outputs Busy and Done are FALSE). This output is TRUE for at least one cycle or until Execute is set to FALSE. The output ErrorID gives more details about the error.

AbbETrig

Input

Module

BYTE

1

Module number 1…10

Output

ErrorID

ERROR_ID

ERROR_ID.NO_ERROR

Error code describing error condition

IdentNum

STRING(15)

‘’

Ident number of the IO-module

IndexNum

STRING(2)

‘’

Index of the IO-module

IOType

STRING(14)

‘’

Type of the IO-module

ManufactWeek

STRING(2)

‘’

Manufactory week of the IO-module

ManufactYear

STRING(2)

‘’

Manufactory year of the IO-module

BAInst

STRING(5)

‘’

Ba inst of the IO-module

FactoryId

STRING(2)

‘’

Manufactory place of the IO-module

SerialNum

STRING(8)

‘’

Serial number of the IO-module